33
All brands and logos are registered trademarks of their respective owners
There is a small display window and a main window. Small display
window displays the parameter, which may be selected by right-clicking
the mouse on this window. Indicators lights, when the voltage is above
or below voltage limits. It warns about dangerous conditions of power
mains, which may cause damage to some equipment.
Figure #16
Main display window displays power characteristics on the
equipment connected: True power (P), energy consumed (E), RMS
current (I rms), peak current (I peak), active impedance (R), RMS
voltage (Vrms), peak voltage (Vpeak), net frequency (Fq). Additionaly, it
shows the cost of energy consumed (money sign) since the previously
set date. Energy and cost values may be reset to zero and current date
will be set as start point, when pressing “Reset” button.